CALL US
0086-371-60922096

steam boiler Agent size of unit btu hr

How to calculate steam boiler capacity?-ZBG Boiler

Jul 28, 2016 · 2.) rated boiler horsepower (BHP- One bhp is the evaporation of 34.5 pounds (= 15.648 kg) of water per hour from a temperature of 212oF (=100oC) into dry saturated steam at the same temperature. Equivalent to 33,472 BTU/h (= 35.291 MJ/h).)

Learn More

What Size Boiler Do I Need For My House? | U.S. Boiler …

Mass Flow Rate (lb/hr) Energy Rate (Btu/hr) Enthalpy (Btu/lb) saturated steam; 420 -12,700 lb/hr or 10 -300 ft/s) ∗Turndown: The range specified as a ratio of highest ∗Sizing: In many applications it is advantageous to size the meter based on flow to improve the effective turndown. ∗(e.g. reducing the 3" meter above to a 2

Learn More

Commercial Boilers | ASAP Appliance Standard Awareness Project

The heated water or steam is circulated through radiators, baseboard units, or fan coils. Commercial boilers are defined as having an input of at least 300,000 Btu/h (British thermal units per hour). THE STANDARD: DOE finalized the current standards for commercial boilers in …

Learn More

Boiler BTU Calculator - SupplyHouse.com

smaller than 10 MMBtu/hr. Overall, the size of the average industrial boiler is 36 MMBtu/hr, compared to 9.6 MMBtu/hr for the average commercial boiler. In addition to the industrial boilers included in the primary analysis, EEA estimates that there are approximately 16,000 industrial boilers in the nonmanufacturing sector with an aggregate capacity of 260,000 MMBtu/hr. Because these units are …

Learn More

Boiler Capacity - Engineering ToolBox

What Size Boiler Do I Need For My House - U.S. Boiler

Learn More

Steam Flow Measurement - US EPA

A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW) hg = enthalpy steam (Btu/lb, kJ/kg) hf = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s)

Learn More

Boiler Bhp Calculation

The Boiler Horsepower (BHP) is the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 oF, with feedwater at 0 Psig and 212 oF. A BHP is equivalent to 33,475 BTU/Hr or 8430 Kcal/Hr and it should be noted that a boiler horsepower is 13.1547 times a normal horsepower. Read More

Learn More

Characterization of the U.S. Industrial/Commercial …

33.475 BTU / hr (9,811 kilowatts) to generate 1 hp. Unfortunately, the common practice is to use the conversion factor of 34.5 lb / hr hp to calculate the boiler generated steam rate without considering that the boiler does not work at atmospheric pressure. ex. 500 hp x 34.5 lb / hp hr = 17,250 lb / hr produced by the boiler. This is what we

Learn More

Water treatment of steam boilers - SlideShare

Aug 02, 2015 · Pounds of Steam per Hour 3. BTU per Hour 1HP means energy to convert 34.5 pounds of water to steam from (and at) 212o F at sea level. High pressure boiler treatment The treatments for high pressure boilers are: 1. Scale control 2. Sludge conditioning 3.

Learn More

BOILER TYPES FOR STEAM APPLICATIONS

BOILER TYPES FOR STEAM APPLICATIONS This article covers the basic difference between common boiler types for high pressure steam applications in the capacity range of 5,000,000 to 100,000,000 Btu/hr (5-100 MMBTU/hr or 120 - 2400 HP). This size range would be the larger commercial, institutional and industrial applications.

Learn More

Steam Calculators: Boiler Calculator

Mar 17, 2015 · [Steam Property Calculator] => Specific Enthalpy = 1,719.4 btu/lbm; Steam Energy Flow = Specific Enthalpy * Mass Flow [ Steam Energy Flow = 68,389 = 1,719.4 btu/lbm * 37.7 klb/hr] Step 2: Determine Feedwater Properties and Mass Flow The feedwater flow rate can be calculated from steam mass flow and blowdown rate

Learn More

lpg consumption calculation for industrial boiler

A safe value is 80%. I work in Imperial, so I've converted the units. Most steam boilers will add. steam boiler on lpg capacity 8 tons per hour gas consumptionCalculate the LPG Consumption per Hour by Burner Size: MJ. 25÷96.5 = 0.259 10 ton gas-fired steam boiler gas consumption per hour and. Whether it …

Learn More

Steam Calculators: Boiler Calculator

Mar 17, 2015 · [Steam Property Calculator] => Specific Enthalpy = 1,323.0 btu/lbm; Steam Energy Flow = Specific Enthalpy * Mass Flow [ Steam Energy Flow = 103,289 = 1,323.0 btu/lbm * 74.0 klb/hr] Step 2: Determine Feedwater Properties and Mass Flow The feedwater flow rate can be calculated from steam mass flow and blowdown rate

Learn More

Fulton Pulse VLP Vertical Low Pressure Steam Boilers

Jun 17, 2011 · See table on Page 15 for required pipe size, based on overall length of pipe from meter plus equivalent length of all fittings. Approximate sizing may be based on 1 cubic foot of natural gas per 1,000 BTU/Hr. input. Section 2. Note Piping schematic consistent with the ANSI/ASME Boiler & Pressure Vessel Code Section IV. Section 2. Caution

Learn More

Unit Conversion--How to Calculate Boiler Horsepower

"Boiler horsepower, a unit of measurement of power of steam boilers" from Wiki. A BHP is equivalent to 33,475 BTU/Hr or 8430 Kcal/Hr and it should be noted that a boiler horsepower is 13.1547 times a normal horsepower. Click on the Icon above will initiate Heat Converter, Pressure Converter, Temperature Converter. Converted HP into LB

Learn More

Boiler BTU Calculator - SupplyHouse.com

Boiler BTU Calculator - Boiler Sizing Calculator - Boiler Sizing - Boiler BTU Calculator [pool7] Boiler BTU Calculator. Q1 Which best describes your heating system? This field is required. Low Temperature Heat (e.g. Radiant Heat) High Temperature Heat (e.g. Baseboard, Fan Coils, Radiators) At this time, we do not carry this unit.

Learn More

Pipe Sizing Steam Supply andCondensateReturn Lines

Assume a boiler operates at a steam pressure of 15 psig and is supplying a 300-ton steam absorption machine which requires a minimum operating pressure of 12 psig. There is a 2 psig pressure drop along the steam mains and the absorption machine is rated to condense 6,000 lbs/hr. The branch line is 50 feet long and has three standard elbows plus

Learn More

Unit Conversion--How to Calculate Boiler Horsepower

The steam boiler size of unit btu hr, on the contrary, are intended for use at pressures below 2.5 MPa. steam boiler size of unit btu hr usually have a capacity of below 20t/h, while water tube ones of 20t/h or more as capacity expansion is possible. steam boiler size of unit btu hr. E-mail: [email protected] Min.Order Quantity: 1 Set. Port: Shanghai

Learn More

Thermodynamic Design of a Fire­Tube Steam Boiler

boiler contains a safety valve that, when the pressure becomes too high due to blockage or overheating, releases the excess steam. Project Description Our engineering team designed a three­pass fire tube steam boiler with a capacity of 5000 kg of steam per hour and a operating pressure of 10 bar.

Learn More

steam boiler Agent capacity sizing for biscuits oven

steam boiler Agent capacity sizing for biscuits oven. Chapter 14 Boilers - Pearson Higher Ed. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW) hg = enthalpy steam (Btu/lb, kJ/kg) hf = enthalpy condensate (Btu/lb, kJ/kg) m = steam

Learn More